The Secretary of State for Trade and Industry, in exercise of the power conferred on her by section 18(5) of the Restrictive Trade Practices Act 1976[1], hereby makes the following Order: -
- (1) This Order may be cited as the Restrictive Trade Practices (Standards) (Services) Order 1998 and shall come into force on 1 July 1998.
| 09-19 | Synthetic aromatic hydrocarbon insulating fluid for use in fluid-filled pressure-assisted cables up to 400kV operating voltage
Issue 2, 1996
|
| 09-22 | Protection of cable installations against the effects of fire
Issue 1, 1997
|
| 12-4 | Terminating equipment for pilot cables subject to induced transient voltages exceeding 650V rms
Amendment 1, 1996 to Issue 1, 1973
|
| 12-25 | Cable trays
Issue 1, 1997
|
| 35-17 | Class X current transformers
Issue 1, 1996
|
| 41-26 | Distribution switchgear for service up to 36kV (cable connected)
Amendment 3, 1997 to Issue 1, 1991
|
| 41-27 | Outdoor distribution switchgear for service up to 36kV (overhead conductor connected)
Amendment 3, 1997 to Issue 1, 1991
|
| 43-2 | Design of steel tower overhead transmission lines at 132kV and higher voltages
Amendment 1, 1996 to Issue 1, 1972
|
| 43-3 | Design of lattice steel transmission towers for overhead lines at 132kV and higher voltages
Amendment 1, 1996 to Issue 1, 1972
|
| 43-6 | Construction of overhead transmission lines on steel towers for 132kV and higher voltages
Amendment 1, 1996 to Issue 2, 1986
|
| 43-8 | Overhead line clearances
Amendment 2, 1996 to Issue 2, 1988
|
| 43-11 | 400kV steel tower transmission lines -specification L. 12 (2 x 700mm2 AAAC per phase) (1 x 425mm2 AAAC earthwire)
Amendment 1, 1996 to Issue 1, 1984
|
| 43-96 | Fasteners and washers for wood pole overhead lines
Corrigendum, 1996 to Amendment 1, 1995 to Issue 2, 1986
|
| 43-97 | Steel supports for single circuit 132kV overhead lines
Amendment 1, 1996 to Issue 1, 1990
|
| 43-99 | Limits and measurement of radio noise from cap and pin insulators
Issue 1, 1997
|
| 43-100 | Conductor tensions and sags
Issue 1, 1997
|
| 43-101 | Line and earth conductors
Issue 1, 1997
|
| 43-102 | Insulators and fittings for 132kV lines
Issue 1, 1997
|
| 43-104 | Spacers for twin and quad line conductors
Issue 1, 1997
|
| 43-105 | Bi-metal connectors for line conductors
Issue 1, 1997
|
| 43-106 | Tubular jumpers and earthing bars for twin line conductors
Issue 1, 1997
|
| 43-107 | Selection of earthwire changeover towers for 400kV lines with 4 x 61/.125 in s.c.a. conductors per phase
Issue 1, 1997
|
| 43-108 | Suspension clamps for conductors
Issue 1, 1997
|
| 43-109 | Bonds for earth conductors
Issue 1, 1997
|
| 43-110 | Tension joints (mid span joints) for conductors
Issue 1, 1997
|
| 43-111 | Non-tension joints and tee connectors for conductors
Issue 1, 1997
|
| 43-112 | Repair sleeves for conductors
Issue 1, 1997
|
| 43-113 | Vibration dampers for conductors
Issue 1, 1997
|
| 43-114 | Anchor clamps for conductors
Issue 1, 1997
|
| 43-115 | Insulators and fittings for 275kV lines
Issue 1, 1997
|
| 43-116 | Insulators and fittings for 400kV lines
Issue 1, 1997
|
| 43-117 | Installation of aluminium current carrying overhead line conductor fittings
Issue 1, 1997
|
| 43-118 | Overhead line erection and maintenance equipment (earthed working)
Issue 1, 1997
|
| 43-119 | Design and use of temporary scaffold guards
Issue 1, 1997
|
| 48-5 | Environmental test requirements for protection relays and systems
Issue 1, 1996
|
| 50-9 | Equipment for work on cables under induced voltage conditions
Issue 1, 1997
|
| 97-1 | Special backfill materials for cable installations
Issue 1, 1997
|
| 98-1 | Surface preparation and coating systems for new plant and equipment
Issue 2, 1997
|
| C97 | Code of Practice on the marking of high-voltage cable routes
1997
|
| G56/1 | Arrangements for access by EA Member Company staff to Railtrack Infrastructure
1996
|
| G75 | Recommendations for the connection of embedded generating plant to Public Electricity Suppliers' distribution systems above 20kV or with outputs over 5MW
1996
|
| G76 | Guide to the Audit and Certification of Suppliers' Quality Management Systems
Part 1: Guide to the Organisation and Operation of Accredited Third Party Certification Bodies
1996
Part 2 (a): Guide to the audit of the Quality Management Systems of Suppliers of High Voltage Switchgear
1996
Part 2 (b): Guide to the Audit of the Quality Management Systems of Suppliers of Low Voltage and High Voltage Cable and Accessories
1996
Part 2 (c): Guide to the Audit of the Quality Management Systems of Suppliers of High Voltage Transformers and Reactors
1997
|
| L43 | Design and use of skycradles at line crossings of motorways, other major roads and railways
1997
|
| P25/1 | The short-circuit characteristics of Public Electricity Suppliers' low voltage distribution networks and the co-ordination of overcurrent protective devices on 230V single phase supplies up to 100A
1996
|
| TELE.2 | Installation of optical cabling in hazardous areas: Overhead power lines
1997
|
| EB/BT.2 | Conditions for BT and Public Electricity Suppliers' joint use of poles
1996
|
This Order approves standards of performance in the provision of services and standards of dimension, design, quality or performance in respect of goods used in providing them which have been adopted by Electricity Association Services Limited. The effect of the Order is that, for the purpose of determining whether an agreement is one to which the Restrictive Trade Practices Act 1976 applies, no account is taken of any term in the agreement by which parties or any of them agree to comply with, or to apply, the standards so approved.
The standards may be inspected at the premises of Electricity Association Services Limited, 30 Millbank, London SW1P 4RD.
[1] 1976 c. 34.back